Understanding Error 67 on Inverters: Causes, Effects, and Solutions 

Why Error 67 Matters in Your Solar System

As Zimbabwe continues to face frequent power outages, many homes and businesses have turned to solar energy for a reliable, cost-effective, and sustainable source of electricity. At the core of any solar power system lies the inverter, which is responsible for converting solar energy into usable AC electricity.

However, as solar technology advances, users sometimes encounter error messages that can disrupt operations. One of the most common and misunderstood of these is Error 67. This error code can cause sudden inverter shutdowns, affect appliance functionality, and limit the full benefits of your solar setup. At Sona Solar Zimbabwe - Solar Experts, we have helped hundreds of clients deal with and permanently solve this issue.

In this detailed guide, we’ll explain what Error 67 means, why it occurs, how it affects your system, and most importantly - how to fix and prevent it.

What Is Error 67 on an Inverter?

Error 67 is a protection error that usually appears when an inverter detects abnormal or excessive electrical load beyond its rated limit. In simple terms, it means that your inverter is overloaded or reading a load irregularity and is attempting to shut down to protect itself.

This error doesn't necessarily mean your system is damaged, it’s a warning that something in your setup is not operating within safe limits.

Key Causes of Error 67

1. Exceeding Inverter Capacity

This is the most common reason behind Error 67. Every inverter has a maximum output capacity, often expressed in kilovolt-amperes (kVA). For example, a 3kVA inverter can only handle a maximum of around 2400–3000 watts at a given time. Connecting multiple high-wattage appliances such as geysers, water pumps, or microwaves simultaneously can cause the inverter to exceed its limit and trigger the error.

2. High Surge Currents from Appliances

Appliances with motors like fridges, freezers, air conditioners, or borehole pumps - often draw much more power at startup than during normal operation. This surge can cause a brief overload, which the inverter reads as unsafe and responds to with an Error 67 shutdown.

3. Faulty or Aging Appliances

Old or faulty appliances can behave unpredictably, pulling more current than usual. A damaged microwave, fan, or washing machine might not operate efficiently and place unnecessary strain on your inverter. This can also confuse the system's sensors, resulting in Error 67.

4. Bad Electrical Wiring

Low-quality or poorly installed wiring can lead to power fluctuations and increased resistance, which might mimic overload conditions even if your appliances are not using excessive power. Issues such as loose connections, undersized wires, or improper grounding can all contribute.

5. Weak or Failing Batteries

Your inverter relies on batteries to supply power. If your batteries are old, damaged, undercharged, or have loose terminals, they won’t be able to support heavy loads. This causes the inverter to pull more current in short bursts, leading to overload detection and Error 67.

6. Firmware and Configuration Errors

Some newer inverter models may require firmware updates to operate correctly. If the system's software is out of date or not calibrated correctly, it might misread load patterns and trigger unnecessary faults.

How Error 67 Affects Your Solar Power System

Even though Error 67 is designed as a protective mechanism, it can be disruptive if not addressed promptly.

1. Appliance Interruptions

When Error 67 occurs, your inverter might stop supplying power entirely or only serve basic loads. Your fridge, lights, computers, and other critical devices might shut down unexpectedly.

2. Loss of Monitoring and Control

In many inverters, this error can also affect communication with mobile apps or cloud-based monitoring systems. This means that you may stop receiving system updates, notifications, or remote control features.

3. Reduced Efficiency

Repeated overloads can degrade your inverter and battery performance over time. Frequent triggering of protective shutdowns can also create instability and reduce the system's overall lifespan.

Diagnosing Error 67 in Your System

The first step in resolving Error 67 is accurate diagnosis. This involves identifying whether the issue is with load size, wiring, batteries, or other components.

Step 1: Check Your Appliance Load

Switch off all appliances and restart your inverter. Then reconnect each device one at a time. If the error returns after a specific appliance is turned on, that appliance may be the source of the overload.

Step 2: Review Your Inverter’s Capacity

Ensure that your total appliance wattage doesn’t exceed the inverter’s rated output. If you have high-surge devices, consult a technician about installing soft starters or load schedulers to minimize strain.

Step 3: Test the Batteries

Use a multimeter to check voltage levels. Low or unstable voltage is a common culprit in triggering overload warnings. Also, inspect for corrosion or damaged terminals.

Step 4: Inspect Wiring and Connections

Have an expert check for hotspots, loose wires, or incorrect cabling sizes. Bad wiring increases electrical resistance and can confuse your inverter’s sensors.

Step 5: Review Firmware and System Settings

Ensure that your inverter software is up to date. Some advanced inverters allow technicians to reset thresholds or change configurations to avoid false alarms.

Solutions to Fix and Prevent Error 67

Once you’ve identified the root cause, you can apply practical solutions to fix and prevent future occurrences of Error 67.

1. Reduce Electrical Load

Only operate a limited number of high-power appliances at one time. For instance, avoid using the microwave, electric kettle, and washing machine simultaneously if your inverter is rated below 5kVA.

2. Schedule Appliance Usage

Use appliances in intervals rather than all at once. For example, run your borehole pump in the morning and your washing machine later in the day.

3. Upgrade Your System

If your power demands have grown beyond your system’s capabilities, it may be time to upgrade your inverter and batteries. We can help you assess and scale up your system based on your needs.

4. Install Soft Starters or Load Limiters

These accessories manage the power surge when appliances start, reducing the chance of overloading the inverter. Sona Solar Expert stocks these essential tools.

5. Maintain Battery Health

Regularly check battery water levels (for flooded batteries), clean terminals, and perform performance tests. Replace old batteries before they begin to fail.

6. Improve Wiring Standards

Ensure all your wiring meets professional standards. Use the correct gauge cables and make sure all connections are tight and corrosion-free.

7. Update Inverter Firmware

Ensure your inverter is running the latest software to prevent unnecessary errors. We provide firmware update services for all popular brands.

Real-Life Example from Sona Solar Clients

One of our customers in Avondale, Harare, was consistently experiencing Error 67 every evening. Our technicians visited the site and discovered that their inverter was connected to several appliances with overlapping usage cycles: a geyser, two fridges, and a washing machine.

We reconfigured the load schedule, installed a soft starter for the borehole pump, and replaced one weak battery. Additionally, we updated the firmware and tightened several loose wiring joints. The client has since enjoyed zero faults and improved power stability.

When to Contact Sona Solar Expert

If you've attempted the above steps and Error 67 persists, don't panic. Contact our technical team for a diagnostic inspection or upgrade recommendation.

We offer:
  • On-site inspections across Zimbabwe
  • Remote troubleshooting
  • Professional installations and system upgrades
  • Stock of quality accessories: inverters, batteries, cables, soft starters, and more

Conclusion: Your Reliable Solar Partner in Zimbabwe

Error 67 is a manageable issue, but only with the right knowledge and support. Whether it’s caused by too much load, faulty appliances, wiring issues, or battery failure, our team at Sona Solar Zimbabwe - Sona Expert is here to guide you every step of the way.

Solar power is a powerful solution for Zimbabwe’s energy needs. And with the right system configuration and maintenance practices, you can enjoy uninterrupted, safe, and efficient power from your investment. Let us help you prevent downtime, reduce frustration, and get the most from your solar system.

Visit us today or call our expert team on 0781190001 for trusted, local support.

Together, we’re powering Zimbabwe - one rooftop at a time.

We Are An Athorized Dealer and Supplier in Zimbabwe.


Solar Experts Zimbabwe is the leading supplier and authorized dealer of Must Solar products in Zimbabwe. As a professional hi-tech enterprise specializing in power inverters, solar power, battery development, manufacturing, sales, and after-service, Must has established its reputation as a trusted brand in the industry. At Solar Experts Zimbabwe, we are proud to bring you Must Solar's top-quality inverters, batteries, and other related solar products.

As an authorized dealer, distributor, and supplier of Must Solar products, we offer a comprehensive range of solar solutions to cater to your energy needs. Our product lineup includes power inverters, solar inverters, solar charge controllers, solar batteries, and more. Whether you are looking for a reliable inverter system or efficient solar panels, we have the products that meet the highest industry standards.

We Are An Athorized Dealer and Supplier in Zimbabwe. Solar Experts Zimbabwe is looking forward to your call or WhatsApp Message.

Please feel free to leave a message on our WhatApp number or alternatively please call us and we will be able to help you straight away. If you would prefer, send us an email with your details and an outline of your enquiry and we will be pleased to come back to you.

We respond to all enquiries usually within 24 hours, but guarantee within 48 hours.

Sona Solar Zimbabwe (Sales Contacts):
1. Yeukai: +263 78 922 2847
2. Natasha: +263 78 293 3586
3. Tafadzwa: +263 78 864 2437
4. David: +263 78 119 0001
5. Faith: +263 77 832 4532
6. Catherine: +263 78 623 1488